Bk-precision 4013B - Manual Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Generátory Bk-precision 4013B - Manual. B&K Precision 4013B - Manual User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - DDS Function Generator

1 Model: 4007B, 4013B DDS Function Generator USER MANUAL

Strany 2 - Safety Summary

4007B/4013B – Operating Manual 10 3 Operating Instructions 3.1 General Description This section describes the displays, controls and connectors

Strany 3 - Compliance Statements

11 3.2 Display Window The function generator has a graphic LCD display that can display up to 124 x 32 dots. When you power-on the unit sin

Strany 4 - CE Declaration of Conformity

4007B/4013B – Operating Manual 12 4. Use termination or impedance-matching devices to avoid reflections. 5. Ensure that attenuators and terminatio

Strany 5

13 The offset voltage has three ranges as follows: Output Voltage Range Constraints of Amplitude + Offset 1.01 volt to 10.00 volts (Vp

Strany 6 - 1 Introduction

4007B/4013B – Operating Manual 14 F4: INTENSITY – Adjusts the intensity of the LCD screen. Valid range is 1 – 9; 9 giving the highest intensity and

Strany 7

15 Use this knob to increase and decrease numeric values. The cursor indicates the low-order position of the displayed value which changes when

Strany 8 - 2 Installation

4007B/4013B – Operating Manual 16 3.13.1 Selecting a Standard Waveform You can select several standard waveforms as: sine, triangle, square. Cr

Strany 9 - 2.8 Signal Connections

17 Recalling Setups To recall stored front-panel setup: 1. Press UTILITY to display the menu. 2. Press F1:RECALL to select the Recall mode.

Strany 10 - 3 Operating Instructions

SERVICE INFORMATION Warranty Service: Please go the support and service section on our website www.bkprecision.com to obtain a RMA #. Return the pr

Strany 11 - 3.5 Output Connections

Index Amplitude, 6, 12, 13, 15 cursor, 14 duty cycle, 13 Errors, 15 factory default, 15 frequency, 12 Impedance Matching, 12 intensity, 14 LCD, 11

Strany 12 - 3.6 MENU Keys

2 Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases of opera

Strany 13

22820 Savi Ranch Parkway Yorba Linda, CA 92887 www.bkprecision.com © 2012 B&K Precision Corp.

Strany 14 - 3.8 Cursor Keys

3 CAUTION: This product uses components which can be damaged by electro-static discharge (ESD). To avoid damage, be sure to follow proper procedu

Strany 15 - 3.13 Quick Start

4 CE Declaration of Conformity The model 4007B and 4013B meet the requirements of 2006/95/EC Low Voltage Directive and 2004/108/EC Electromagnet C

Strany 16

5 1 INTRODUCTION ... 6 1.1 Introduction ...

Strany 17

4007B/4013B – Operating Manual 6 1 Introduction 1.1 Introduction This manual contains information required to operate the B&K Precision mod

Strany 18 - LIMITED THREE-YEAR WARRANTY

7 Harmonic Distortion DC – 100 kHz, -55 dBc 100 kHz – 1 MHz, -45 dBc 1MHz – 7 MHz, -30 dBc DC – 100 kHz, -55 dBc 100 kHz – 1 MHz, -45 dBc

Strany 19

4007B/4013B – Operating Manual 8 2 Installation 2.1 Introduction This section contains installation information, power requirements, initial in

Strany 20

9 2.6 Fuse Replacement There is a 1A, 250V rated slow blow fuse at the AC input. Should the fuse ever get blown, follow the steps below to

Příbuzné modely 4007B - Manual

Komentáře k této Příručce

Žádné komentáře